Retrotec DU200 DucTester Testing Procedures to meet EnergyS Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Měřící nástroje Retrotec DU200 DucTester Testing Procedures to meet EnergyS. Retrotec DU200 DucTester Testing Procedures to meet EnergyStar Standards User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 4
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Page 1 of 4
PR115 rev-2011-09-02
4.1 Total measured duct leakage to meet ENERGY STAR standards
1. With air-handler off, connect DucTester with
Mid-Range plate, and seal registers.
2. On the DM-2* digital gauge:
a. Press [Mode] until cfm/100ft
2
appears.
If unavailable, press [Setup], “Mode Setup”.
b. Press [Device] to get “Retrotec DU200”
c. Press [Range Config] to get "Mid".
*See page 4 for Setup instructions.
3. Press [Enter Area], input the conditioned floor
area, press [Enter], for each house.
4. Press [Set Pressure] [25] [Enter].
5. Press the [@] key until “@ 25 Pa” is displayed.
6. Leakage must be corrected if above 6.
Measure leakage to outdoors if above 4.
CFM at 25 Pa per 100 sq. ft.
Floor area, sq. ft.
>8 fail, >5 test to outdoors
Less than 1200
>6 fail, >4 test to outdoors
More than 1200
This test measures
total duct leakage in
CFM25 per 100 sq. ft.
of conditioned floor
area.
Pink denotes
pressurized area
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - Less than 1200

Page 1 of 4 PR115 rev-2011-09-02 4.1 Total measured duct leakage to meet ENERGY STAR standards 1. With air-handler off, conn

Strany 2 - Page 2 of 4

Page 2 of 4 4.2 Measured duct leakage to outdoors to meet ENERGY STAR standards If Total Leakage is above 4, perform this test which measures le

Strany 3 - Volume], enter volume in

Page 3 of 4 4.3 Envelope leakage test to meet ENERGY STAR standards 1. Remove Grill Mask and DucTester. 2. Connect the Door Fan to blow outdoo

Strany 4 - Page 4 of 4

Page 4 of 4 Gauge set up to meet ENERGY STAR standards The first time you use the DM-2, press [Auto Zero] to turn it “On,” and press [Time Avg] unti